WebFor example, with a flow temperature of 80°C and return temperature of 50°C using natural gas, ... If the flow out of the boiler is 70°C and return is 40°C then the average system temperature is likely to be 55°C, lower than if the system was operating at say 80/60°C. This means that the heat emitter needs to be larger to deliver ... WebJan 17, 2013 · Country. 17 Jan 2013. #4. If the return is 55° C or lower then the boiler will be condensing well. That means the flow can be up to 75° C but the lower it is the more efficient the boiler operation. Weather compensation aims to heat with the lowest flow temperature necessary to provide the required heating. Tony.
Optimizing hot water systems with condensing boilers
WebDec 23, 2009 · I have a digital laser thermometer. When I point this at the 22mm copper pipes under the boiler ( the flow and return ) they never read more than 35c yet if I measure the surface temp on the radiator closest to the boiler it reads 66c. It's because the thermometer averages the temperature over a larger area than just the spot of the laser. WebJan 10, 2024 · jamesBen80. I've just installed 2 digital temperature probes on the boiler flow and return pipes, to try and ensure the boiler is condensing, below the magic number ( what ever it is, but that's another discussion). When the system start up from cold in the morning the temperature difference between flow and return is quite large, flow is 50C ... monomax モノマックス 2022年4月号
Lower the flow temperature on your boiler to save 12% - The Heating H…
WebAug 1, 2000 · The boiler pump must provide the total flow of the system (in this case, at least 40 gpm) plus whatever flow is necessary to keep the return water temperature as high as desired. If the piping in the zone has less resistance to flow than the pump head rating at the flow design, the pump will provide more flow for the pipe’s given resistance. WebSep 11, 2024 · For condensing boilers, you need a return water temperature of 80°F or lower in order to achieve 97% efficiency. (Look at the efficiency curves from any common condensing boiler manufacturer to see this.) ... It follows that the minimum flow temperature of the boiler should be 65 C (providing that the cylinder stat is set to 60 C) … WebFeb 27, 2024 · I have set the pump run on to 20 mins which means the pump runs all the time that the system is calling. I have a flow/return delta of about 15C which means the boiler flow temperature reaches a maximum of 70C. System maintains room temperature well but heat up time from cold is a bit longer and DHW recharge time has extended 10 … monomax モノマックス 2023年 3月号